missing translation for 'onlineSavingsMsg'
Learn More

Applied Biosystems™ TaqMan™ Copy Number Reference Assay, human, RNase P
GREENER_CHOICE

Human TaqMan™ Copy Number Reference Assays are run with human TaqMan™ Copy Number Assays in a duplex real-time PCR reaction to detect and measure copy number variations (CNVs) and smaller regions in the human genome.

Brand:  Applied Biosystems™ 4403326

821.06 NOK valid until 2024-12-20
Use promo code "21651" to get your promotional price.


 View more versions of this product

Product Code. 10535585

  • 1478.00 NOK / Each

Please to purchase this item. Need a web account? Register with us today!

Explore more special offers
This item is not returnable. View return policy

Description

Description

  • Assays are run with human TaqMan™ Copy Number Assays in a duplex real-time PCR reaction
  • Used to detect and measure copy number variations (CNVs) and smaller regions in the human genome
  • Two options for genes that can be used as endogenous reference genes in humans are offered: RNase P and TERT
  • Designed to unique genomic sequences in the reference genome assembly (build GRCh38) and are required for relative quantitation of copy number targets
  • TaqMan™ Copy Number Assays quantitate the gene of interest and normalize to an endogenous reference gene known to be present in two copies in a diploid genome
  • Please note that TaqMan™ Copy Number Reference Assays are species specific.
  • Assays should be stored at -15°C to -25°C in the dark
  • Minimize freeze-thaw cycles

TaqMan™ Copy Number Reference Assay RNase P

  • Recommended as the standard reference assay for copy number analysis
  • This assay detects the Ribonuclease P RNA component H1 (H1RNA) gene (RPPH1) on chromosome 14, cytoband 14q11.2
  • The assay location is chr.14:20343370 on build GRCh38
  • It has an 87 bp amplicon that maps within the single exon RPPH1 gene

TaqMan™ Copy Number Reference Assay TERT

  • An alternative reference assay recommended in the event that the RNase P assay functions poorly with a sample
  • This could be due to chromosomal aberrations or other issues
  • This assay targets the telomerase reverse transcriptase (TERT) gene located on chromosome 5, cytoband 5p15.33
  • The assay location is chr5:1253257 on build GRCh38
  • It has an 88 bp amplicon that maps within exon 16 of the TERT gene
TRUSTED_SUSTAINABILITY
Specifications

Specifications

None
Control Primer-Probe Set(s)
Frozen
Low
Standard
Sustainable packaging
VIC
Configurable Assay
RNase-Free, DNase-Free
Human
RNase P
750 Reactions
None
Primer-probe
Tube
qPCR
RPPH1
TAMRA™ Quencher (3'), VIC™ (5')
TaqMan™
HPLC
Ambient Temperature
750 Reactions
20X
Product Suggestions

Product Suggestions

Videos
SDS
Documents

Documents

Certificates
Special Offers

Special Offers

For Research Use Only. Not for use in diagnostic procedures.