Tandem Mass Tag Reagents
Tandem Mass Tag Reagents
- (23)
- (17)
- (37)
- (2)
- (11)
- (7)
- (3)
- (5)
- (1)
- (2)
- (3)
- (1)
- (2)
- (2)
- (2)
- (9)
- (1)
- (2)
- (2)
- (2)
- (2)
Filtered Search Results
Thermo Scientific™ Super Heavy TMTpro™ Label Reagent
The amine-reactive Super Heavy TMTpro Label Reagent is an alternate form of TMTpro that contains twice the number of heavy isotopes for labeling peptides. When used with TMTpro-labeled samples, it enables 2D TMTpro multiplexing applications for targeted quantitation by mass spectrometry.
Thermo Scientific™ TMTpro™ 16plex Label Reagent Set
The Thermo Scientific TMTpro 16plex Label Reagent Set enables multiplexing of up to 16 samples for multiplexed protein identification and quantitation using tandem mass spectrometry (MS/MS).
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Peptide |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Detection Method | Mass Spectrometry |
Product Line | TMT™ |
Thermo Scientific™ 1M TEAB and 50% Hydroxylamine Buffers for TMT Experiments
Common TMT buffers such as 1M Triethylammonium bicarbonate (TEAB) and 50% Hydroxylamine for isobaric mass tag labeling experiments.
Content And Storage | Store protected from direct sunlight in a dry, cool, and well-ventilated area. |
---|---|
Workflow Step | Protein Labeling |
Product Type | Buffer |
Starting Material | Cell Lysate |
Product Line | TMT™ |
Thermo Scientific™ TMT10plex™ Isobaric Label Reagents and Kits
TMT10plex Isobaric Label Reagents and Kits contain ten isobaric compounds with the same mass and chemical structure (i.e., isotopomeric) composed of an amine-reactive NHS-ester group, a spacer arm, and a mass reporter.
For Use With (Equipment) | Mass Spectrometer |
---|---|
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Detection Method | Mass Spectrometry |
Product Line | TMT10plex™ |
Thermo Scientific™ TMT11-131C Label Reagent
Tandem mass tag (TMT) reagents are specially designed to enable identification and quantitation of proteins in different samples using tandem mass spectrometry.
Detection Method | Mass Spectrometry |
---|
Thermo Scientific™ TMTpro 18-plex, TMTpro-134C, and TMTpro-135N Label Reagents
TMTpro label reagents are the next generation of tandem mass tags, designed to increase the level of sample multiplexing without compromising on protein identification and quantitation.
Product Type | Isobaric Label Reagent Set |
---|---|
Detection Method | Mass Spectrometry |
Thermo Scientific™ Pierce™ TMT11plex Yeast Digest Standard
Thermo Scientific Pierce TMT11plex Yeast Digest Standard is a lyophilized yeast peptide mixture of four congenic yeast strains labeled with TMT11plex reagents to monitor LC-MS/MS system performance for multiplexed quantitation.
Shipping Condition | Wet Ice |
---|---|
Workflow Step | MS System Performance |
Form | Lyophilized Powder |
Final Product Type | MS Standard |
Product Type | Digest Standard |
For Use With (Equipment) | Mass Spectrometer |
Starting Material | Peptides |
Detection Method | Mass Spectrometry |
Product Line | Pierce™ |
Thermo Scientific™ TMT™ Elution Buffer and Anti-TMT Resin
For enhanced enrichment, use Thermo Scientific TMT Elution Buffer with Immobilized Anti-TMT Resin for peptides that have been chemically labeled with Tandem Mass Tag (TMT) Isobaric Label Reagents for multiplexed protein quantitation using tandem mass spectrometry.
Workflow Step | Protein Labeling |
---|---|
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |
Product Line | TMT™ |
Thermo Scientific™ TMTsixplex™ Isobaric Label Reagent Set
Amine-reactive Thermo Scientific TMT Isobaric Mass Tagging Kits and Reagents enable multiplex quantitation of proteins extracted from cells and tissues from up to 6 samples using tandem mass spectrometry.
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Protein |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |
Product Line | TMTsixplex™ |
Thermo Scientific™ iodoTMTsixplex™ Isobaric Mass Tagging Kit
Use Iodoacetyl Tandem Mass Tag™ (iodoTMT™) Isobaric Label Reagents to label up to six sulfhydryl-containing peptides for simultaneous quantitation of proteins using tandem mass spectrometry.
Thermo Scientific™ TMTduplex™ Isobaric Label Reagent Set, 5 x 0.8 mg
TMTduplex™ Isobaric and Isotopic Mass Tagging Reagent sets enable 2-way labeling experiments of extracted proteins using tandem mass spectrometry.
Thermo Scientific™ TMTpro™ Zero Label Reagent
Thermo Scientific TMTpro Zero Label Reagent serves as a 'light' tag for MS-level peptide quantitation for method optimization or use with the TMTpro 16 plex Label Reagent Set.
Shipping Condition | Dry Ice |
---|---|
Workflow Step | Protein Labeling |
Final Product Type | Peptide |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Peptides |
Detection Method | Mass Spectrometry |
Product Line | TMT™ |
Thermo Scientific™ TMTzero™ Label Reagent, 5 x 0.8 mg
The Thermo Scientific TMTzero Label Reagent serves as a 'light' tag for MS-level peptide quantitation similar to duplex isotopic metabolic labeling, such as SILAC, or isotopic dimethylation labeling.
Thermo Scientific™ aminoxyTMTsixplex™ Label Reagent Set
The carbonyl-reactive Thermo Scientific™ aminoxyTMT™ (Tandem Mass Tag™) Label Reagents enable multiplexed characterization and quantitation of carbonyl-containing biomolecules (carbohydrates, steroids, oxidized proteins) by mass spectrometry (MS).
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Protein |
For Use With (Equipment) | Mass Spectrometer |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |
Product Line | aminoxyTMTsixplex™ |
Thermo Scientific™ iodoTMTsixplex™ Isobaric Label Reagents and Kits
Use Iodoacetyl Tandem Mass Tag (iodoTMT) Isobaric Label Reagents to label sulfhydryl-containing peptides for the multiplexed detection and quantitation of cysteine modification using tandem mass spectrometry analysis.
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Protein |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |