Filtered Search Results
Thermo Scientific™ TraceGOLD TG-5HT GC Columns
Thermo Scientific™ TraceGOLD TG-5HT GC Columns offer extended operation up to 400°C, ideal for high temperature GC applications.
Max. Temperature | 380/400°C |
---|---|
Stationary Phase | TraceGOLD™ TG-5 HT |
Polarity | Low-Polar |
For Use With (Application) | Pesticides Analysis,GC/MS for Pesticides,GC/MS for Residual Solvents, Solvents, and Solvent Impurities |
USP Type | G27, G36 |
Product Line | TraceGOLD |
Thermo Scientific™ TraceGOLD TG-5MS GC Columns
Employ the most widely used MS phase in gas chromatography with the 5% phenyl phase Thermo Scientific™ TraceGOLD™ TG-5MS GC Column.
Stationary Phase | TraceGOLD™ TG-5 MS |
---|---|
USP Type | G27, G36 |
Thermo Scientific™ TRACE™ TR-5MS GC Columns
Choose these colums that feature a popular GCMS phase for many applications.
Stationary Phase | Trace™ TR-5 MS |
---|---|
Polarity | Non-Polar |
USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD™ TG-WaxMS GC Columns
Analyze FAMEs with excellent thermal stability using this column.
Max. Temperature | 240/260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS |
Polarity | Polar |
USP Type | G14, G15, G16, G20, G39 |
Thermo Scientific™ TraceGOLD™ TG-624 and TG-624SilMS GC Columns
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Polarity | Mid-Polar |
---|---|
USP Type | G43 |
Thermo Scientific™ TRACE™ TR-Wax GC Columns
Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column.
Stationary Phase | Trace™ TR-WAX |
---|---|
Polarity | Polar |
USP Type | G16, G20 |
Thermo Scientific™ TraceGOLD TG-5SilMS GC Columns
Incorporates phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation.
Max. Temperature | 330/350°C |
---|---|
Stationary Phase | TraceGOLD™ TG-5 SilMS |
Polarity | Low-Polar |
For Use With (Application) | GC/MS Applications Using Ion-Trap Systems,GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates,GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons |
USP Type | G27, G36 |
Thermo Scientific™ TRACE™ TR-FAME GC Columns
For separation of cis/trans isomers and FAMEs with various degrees of unsaturation, choose this low-bleed, high-polarity column optimized for FAME analysis.
Max. Temperature | 250/260°C |
---|---|
Stationary Phase | Trace™ TR-FAME |
Polarity | Polar |
Product Line | TRACE |
Thermo Scientific™ TRACE™ TR-5 GC Columns
Choose these excellent starting columns for method development, capable of performing most required separations.
Stationary Phase | Trace™ TR-5 |
---|---|
Polarity | Non-Polar |
USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD™ TG-5MS Guard GC Columns with SafeGuard
Extend column lifetime and get more consistent results over a longer period of time.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MS |
Polarity | Low-Polar |
Temperature Range | -60°C to +330/350°C |
For Use With (Application) | Active Compounds Analysis,GC/MS for Analysis of Active Compounds |
USP Type | G27, G36 |
Thermo Scientific™ TRACE™ GC Columns for Pesticides
Identify organophosphate and organochlorine pesticides with high performance, sensitivity and reproducibility.
Max. Temperature | 280/300°C |
---|---|
Length (Metric) | 30 m |
Diameter (Metric) | 0.25 mm |
Diameter (Metric) Inner | 0.25 mm |
For Use With (Application) | Pesticides Analysis |
Film Thickness | 0.25 μm |
USP Type | G43 |
Product Line | TRACE |
Thermo Scientific™ TRACE™ TR-WaxMS GC Columns
Use this low-bleed, highly stable polar GC column for high-polarity separations for MS analysis.
Max. Temperature | 280/300°C |
---|---|
Stationary Phase | Trace™ TG-WAXMS |
Polarity | Polar |
For Use With (Application) | GC/MS for Aromatic Hydrocarbons, Alcohols, Esters, Aldehydes, and Ketones,GC/MS for Food Additives and Essential Oils |
USP Type | G16 |
Thermo Scientific™ TRACE™ GC Columns for Dioxin and PCB Analysis
Analyze dioxins and PCBs with high-resolution GC/MS for unsurpassed performance and reproducibility.
Max. Temperature | 360/370°C |
---|---|
Diameter (Metric) | 0.25 mm |
Diameter (Metric) Inner | 0.25 mm |
For Use With (Application) | Furan (PCDF) Analysis,GC/MS for Furan (PCDF) Analysis,GC/MS for PCB Congener Analysis |
USP Type | G27, G36 |
Product Line | TRACE |
Thermo Scientific™ TraceGOLD™ TG-5MT Metal GC Columns
Greater stability and inertness at elevated temperatures and when working with highly active compounds.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MT |
Polarity | Low-Polar |
USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD TG-35MS GC Columns
Use these columns for a higher phenyl content that provides useful elution order and retention time changes.
Max. Temperature | 300/320°C |
---|---|
Stationary Phase | TraceGOLD™ TG-35 MS |
Polarity | Mid-Polar |
USP Type | G42 |